Proportional Elec-HYD. Controls

Proportional Electro-Hydraulic Relief Valves

Manufacturer:
UpdateTime:2014-01-12
Download:
Move the mouse to view larger image

  This valve is derived by combining a small, high-performance 1/8 proportional electro-hydraulic pilot relief valve with a specially developed low-noise relief valve.With this valve, it is possible to regulate the system pressure inproportion to the input current. Note that this valve is used in conjunction with the applicable power amplifier.

 


JIS Hydraulic Graphic Symbol
 

 

  Specifications:

 

 

  Model Number Designation:

 

 

  Instructions:

 

  1.Safety Valve——The pressure of the safety valve for EBG-03 is preset at the value equal to the upper limit of the pressure adjustment range plus 2 MPa (290 PSI) subject to a flow rate of 50 L/min (13.2 U.S.GPM).
 

  2.The same for EBG-06 is preset at the value equal to the upper limit of the pressure adjustment range plus 3.5 MPa (510 PSI) subject to a flow rate of 100 L/min (26.4 U.S.GPM). The same for EBG-10 is preset at the value equal to the upper limit of the pressure adjustment range plus 4 MPa (580 PSI) subject to a flow rate of 200 L/min (52.8 U.S.GPM).

 

  In case where the upper limit of operating pressure is low or the upper limit of flow rate to be used is different from the specified maximum flow, please adjust and determine the setting pressure of the safety valve at the value calculated from the following formula.
 

  Setting pressure = (Operating pressure upper limit) + (Additional pressure indicated the picture)
To lower the setting pressure, turn the safety valve pressure adjustment screw anti-clockwise. After adjustment, be sure to tighten the lock nut.

 

  Notes: Please call our company telephone 021-67687301, 67687302. For Buy the "Proportional Electro-Hydraulic Relief Valves"products. Browse this webpage carefully to know more about Proportional Electro-Hydraulic Relief Valves.