Proportional Elec-HYD. Controls

Proportional Electro-Hydraulic Relieving and Reducing Valves

Manufacturer:
UpdateTime:2014-01-12
Download:
Move the mouse to view larger image


JIS Hydraulic Graphic Symbol

  Specifications:

 

 

  Model Number Designation:

 

 

  Instructions :

 

  1. Primary Pressure Required for Preselected Pressure The primary pressure must be 1 MPa (145 PSI) higher than the preselected pressure.

 

  2. Drain Back Pressure Check that the drain back pressure does not exceed 0.2 MPa (29 PSI).

 

  3. Trapped Oil Volume

 

  The recommended secondary side trapped oil volume is about 20 liters (5.28 U .S.Gallons). Note that the trapped oil volume must not be lower than 1.4 liters (.37 U.S.Gallons).

 

  Notes: Please call our company telephone 021-67687301, 67687302. For Buy the "Proportional Electro-Hydraulic Relieving and Reducing Valves"products. Browse this webpage carefully to know more about the Proportional Electro-Hydraulic Relieving and Reducing Valves.